Ex vivo and in vivo study of Kowa HA-2 applanation tonometer in the measurement of intraocular pressure in dogs
DOI:
https://doi.org/10.5433/1679-0359.2016v37n2p797Keywords:
Applanation tonometer, Dogs, Glaucoma, Kowa ha-2 tonometer, Ocular manometry, Uveitis.Abstract
The objective of this study was to evaluate the use of the Kowa HA-2 applanation tonometer in measuring intraocular pressure (IOP) in dogs. Twenty eyes were used in an ex vivo study in which the calibration curve for manometry vs. tonometry was determined by artificially raising the IOP in 5 mmHg increments up to 60 mmHg (10-60 mmHg). Both eyes of 10 anesthetized dogs were studied in vivo to compare manometry vs. tonometry. In the ambulatory study, 168 healthy eyes, 74 eyes with glaucoma and 60 eyes with uveitis were evaluated by tonometry, which was performed with topical anesthesia and 1% fluorescein eye drops for the formation of fluorescein semicircles. The ex vivo study showed an excellent correlation coefficient (r2= 0.993) between the aneroid manometer and the Kowa HA-2 tonometer. In the in vivo study, there was no significant difference (P>0.05) between the IOP values by manometry and tonometry, showing the excellent accuracy of the Kowa HA-2 tonometer. In the ambulatory study using the Kowa HA-2 tonometer, the IOP values (mean±SD, in mmHg) were 15.1±1.8 (12.0 – 20.0) for the healthy eyes, 25.2±4.0 (20.0 – 38.0) for glaucomatous eyes and 10.1±2.3 (5.0 – 13.7) for eyes with uveitis. There was a strong correlation between the IOP values obtained by direct ocular manometry and those from the Kowa HA-2 tonometer. In the ambulatory study, the IOP values measured by the tonometer were compatible for healthy eyes and for eyes with glaucoma or uveitis. We conclude that Kowa HA-2 applanation tonometer is accurate and practical for IOP measurement in dogs.Downloads
Published
How to Cite
Issue
Section
License
![Creative Commons License](http://i.creativecommons.org/l/by-nc/4.0/88x31.png)
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
O Copyright dos manuscritos publicados pertence ao periódico. Como são publicados em um periódico de acesso aberto, eles estão disponíveis gratuitamente, para uso privado ou para fins educacionais e não comerciais.
A revista tem o direito de fazer, no documento original, alterações referentes às normas lingüísticas, ortografia e gramática, com o objetivo de garantir as normas padrão do idioma e a credibilidade da revista. No entanto, respeitará o estilo de escrita dos autores.
Quando necessário, alterações conceituais, correções ou sugestões serão encaminhadas aos autores. Nesses casos, o manuscrito deve ser submetido a uma nova avaliação após revisão.
A responsabilidade pelas opiniões expressas nos manuscritos é inteiramente dos autores.